服务搜索 SEARCH
IEC 60598-2-4
作者:TECERT    发布于:2020-01-06 02:53:28    检测认证一站式服务    收藏:Ctrl+D
摘要:IEC 60598-2-4 Luminaires - Part 2-4: Particular requirements - Portable general purpose luminaires 联系我们:info@tecert.com 安排测试 / Contact us for testing.
标准编号 Standard/Code 标准名称 Standard Title
IEC 60598-2-4 Luminaires - Part 2-4: Particular requirements - Portable general purpose luminaires

IEC 60598-2-4:2017 RLV contains both the official IEC International Standard and its Redline version. The Redline version is not an official document, it is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.

IEC 60598-2-4:2017 specifies requirements for portable general purpose luminaires for indoor and/or outdoor use (e.g. garden use), other than handlamps, designed to be used with or incorporating electrical light sources on supply voltages not exceeding 250 V.

This third edition cancels and replaces the second edition published in 1997. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
 - alignment with IEC 60598-1;
 - modification of the scope, classification and requirements to cover portable luminaires for both indoor and outdoor applications, by introducing the requirements already listed in IEC 60598-2-7;
 NOTE  In this edition of IEC 60598-2-4 all requirements listed in IEC 60598-2-7 have been incorporated. As a consequence, IEC 60598-2-7 will be withdrawn after publication of this standard.
 - modification of the scope to cover all electrical light sources (it was previously limited to tungsten filament, tubular fluorescent and other discharge lamps);
 - introduction of the symbol for luminaires which are other than ordinary, but suitable for indoor applications only (e.g. luminaire using PVC cable);
 - modification in the detail of test to clarify that the stability test on an inclined plane (see 4.7.3) shall be carried out with the light source(s) in place;
 - modification of the minimum degree of protection against dust and moisture for portable luminaires for outdoor use from IPX3 to IPX4 (see 4.5.2); as a consequence, the requirements for cable entry position, as given in IEC 60598-2-7:1982, 7.6.3 were deleted as they are covered by IPX4;
 - modification of the requirements for the acceptance criteria of plug and socket outlet;
 - modification of the IP test requiring the most unfavourable of the overturned positions to cover all classes (and not only class II luminaires as in 7.13.1 of IEC 60598-2-7:1982).

Test Requirement 测试要求:

标记
防尘、防固体异物和防水
防触电保护
接地规定
接线端子
结构
绝缘电阻和介电强度
耐久性试验和热试验
耐热、耐火和耐电痕
爬电距离和电气间隙
外部接线和内部接线

Sample Size 样品数量 / 送样规格: 6pcs
Lead Time / TAT (Turn Around Time) 测试周期: 常规服务 Regular service 7-9 working days

Report Summary 报告摘要:

 